Enable technical lineage via Edge
To use technical lineage via Edge, you must first enable it.
If you have multiple databases with the same name, you can also use the Collibra system name setting to instruct Edge to use the system or server name of a data source to match to the System asset that you create in Data Catalog.
These settings are general configurations that apply to all technical lineage features on Edge.
Prerequisites and permissions
The settings on the Services Configuration page are also available in the Collibra service settings in Collibra Console.
Note The Services Configuration page is not available by default.
Steps
Depending on your environment, follow this procedure either on the Services Configuration tab of the Collibra settings or in Collibra Console:
-
Open the Services Configuration page.
-
On the main toolbar, click
→
Settings.
The Collibra settings page opens. - Click Services Configuration.
- Click Edit configuration.
Open the DGC service settings for editing:- Open Collibra Console.
Collibra Console opens with the Infrastructure page. - In the tab pane, expand an environment to show its services.
- In the tab pane, click the Collibra Platform service of that environment.
- Click Configuration.
- Click Edit configuration.
-
On the main toolbar, click
- In the Lineage on Edge section, enter the following information:
Setting
Description
DGC user name The user name to be used to ingest metadata in Data Catalog via Collibra Data Lineage service. DGC user password The password for the user to be used to ingest metadata. Collibra system name Indicates whether you want to use the system or server name of a data source to match to the System asset that you create in Data Catalog.
We recommend setting the value to
True only if you have multiple databases with the same name.
False (default value)
- Edge ignores the system or server names that you specify, for example:
- The Collibra system name field in a technical lineage capability.
- The
collibraSystemName
property in the Source Configuration field of a technical lineage capability. - The System field on the Synchronization Configuration page when you synchronize a capability.
True
- The technical lineage via Edge uses the system or server names that you specify, for example:
- The Collibra system name field in a technical lineage capability.
- The
collibraSystemName
property in the Source Configuration field of a technical lineage capability. - The System field on the Synchronization Configuration page when you synchronize a capability.
Important If you use Edge and the CLI lineage harvester to generate the technical lineage, the following values must be the same:- The value for this setting.
- The value of the
useCollibraSystemName
property in the lineage harvester configuration file.
If the values are different, the technical lineage synchronization will fail.
- Click Save all.