Edit the buffer settings of the Collibra DGC statistics

You can edit the buffer settings of the Collibra Platform

Depending on your environment, follow this procedure either on the Services Configuration tab of the Collibra settings or in Collibra Console:

Important You can't edit the service configuration from the Settings page in the latest UI. If you use the latest UI, you can edit the service configuration only in Collibra Console. For more information, go to Collibra service configuration settings.

Prerequisites

Steps

  1. Open the Services Configuration page.
    1. On the main toolbar, click Products iconCogwheel icon Settings.
      The Collibra settings page opens.
    2. Click Services Configuration.
    3. Click Edit configuration.
    Open the DGC service settings for editing:
    1. Open Collibra Console.
      Collibra Console opens with the Infrastructure page.
    2. In the tab pane, expand an environment to show its services.
    3. In the tab pane, click the Collibra Platform service of that environment.
    4. Click Configuration.
    5. Click Edit configuration.
  2. In the Statistics configuration section, make the necessary changes.
    SettingDescription
    Buffer size

    The maximum amount of statistics entries that the buffer can contain before saving them in the database.

    The default value is 10.

    Buffer flush time

    The maximum amount of time in milliseconds to keep statistic entries in memory before saving them in the database.

    The default values is 10,000.

    Cron map

    List of statistics, listed by their Cron name, and a Cron interval.

    These are the default values:

    Field keyField value

    workflow-task

    0 59 23 * * ?

    active-users

    0 0/15 * * * ?

    term-count

    0 59 23 * * ?

    vocabulary-count

    0 59 23 * * ?

    page-hit

    0 0 * * * ?

    task-count

    0 0 * * * ?

    If you create an invalid cron pattern, Collibra stops responding.

  3. Click Save all.